SmartGen HAT520N ATS controller


Price:
$100
 More payment options

Description

SmartGen HAT520N ATS controller

The powerful Microprocessor contained within the HAT520N ATS controller allows for precision voltage (2-way 3-phase/single phase) measuring and make accurate judgment on abnormal voltage (power lost, over/under voltage, over/under frequency, loss of phase, phase sequence wrong) and control ATS to transfer after the delay has expired. This controller is suitable for NO Breaking ATS. When 1# power is abnormal, the controller will send a signal to start Genset after the “1# abnormal delay” has expired. “Three remote” (remote control, remote measurement, and remote communication) function can be implemented with the help of the LINK communication port.

  • Power Supply:AC(170~277)V
  • Case Dimensions:139*120*50(mm)
  • Panel Cutout:130*111(mm)
  • Operating Temp. :(-25~+70)℃
  • Weight:0.49kg

PERFORMANCE AND CHARACTERISTICS

  1. HAT520N ATS controller owns performance and characteristics are shown as below,

  2. Measure and display 2-way 3 phase Voltage and Frequency:

    1#                                 2#

    Line voltage   (Uab, Ubc, Uca)    Line voltage   (Uab, Ubc, Uca)

    Phase voltage (Ua, Ub, Uc)        Phase voltage (Ua, Ub, Uc)

    Frequency    Hz                 Frequency    Hz

  3. ver/under voltage, loss of phase, phase sequence wrong, over/under frequency protection function. As default, phase sequence wrong protection and over/under frequency protection are disable; however, users can set the protection function as need.

  4. Parameters can be set via PC software using SG72 module (USB to LINK) or other converse module.

  5. The voltage normal delay of 1# or 2#can be set in (0~60) seconds and the Genset start delay can be set in (0~3600) seconds.

  6. The voltage abnormal delay of 1# or 2#can be set in (0~60) seconds and the Genset stop delay can be set in (0~3600) seconds.

  7. “1# power priority”, “Auto/Manual”, “No priority” and “2#power priority” can be set via controller front panel.

  8. Closing output signal can be set as on intervals or as continuous output.

  9. Applicable for 2 isolated neutral line.

  10. Auto/Manual mode. In manual mode, ATS transfer 1# switch or 2# switch can be implemented via panel pushbutton.

  11. LEDs mounted on front panel can clearly show ATS running status.

  12. The output contactor capacity of 1# and 2#power supply transfer relay (1#CLOSE, 2#CLOSE) is 16A AC250V, volts-free contact, can be directly used in driving switch to transfer.

  13. The output contactor capacity of Genset start relay (GENS START) is 7A AC250V/7A DC28V, volts-free N/C contact.

  14. Suitable for various AC systems (3 phase 4-wires, 2-phase 3-wires and single-phase 2-wire).

  15. Modular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting,compact structure with easy installation.

Payment & Security

American Express Apple Pay Google Pay Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Estimate shipping

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

You may also like

Recently viewed