SmartGen HAT530N ATS Controller for NO Breaking ATS and ONE Breaking ATS


Price:
$79
 More payment options

Description

SmartGen HAT530N ATS controller

The powerful Microprocessor contained within the HAT530N ATS controller allows for precision voltage (2-way 3-phase/single phase) measuring and make accurate judgment on abnormal voltage (power lost, over/under voltage, over/under frequency, loss of phase, phase sequence wrong) and control ATS to transfer after the delay has expired. This controller is suitable for NO Breaking ATS and ONE Breaking ATS.

  • Case Dimensions:139*120*50(mm)
  • Panel Cutout:130*111(mm)
  • Operating Temp. :(-25~+70)℃
  • Weight:0.51kg

Performance and characteristics:

  1. Measure and display 2-way 3 phase Voltage and Frequency

  2. Over/under voltage, loss of phase, phase sequence wrong, over/under frequency protection function. As a default, phase reverse sequence protection and over/under frequency protection are disabled; however, users can set the protection function as need.

  3. Parameters can be set via PC software using the SG72 module (USB to LINK) or another converse module.

  4. The voltage normal delay of 1# or 2# can be set in (0~60) seconds and the Genset start delay can be set in (0~3600) seconds.

  5. The voltage abnormal delay of 1# or 2# can be set in (0~60) seconds and the Genset stop delay can be set in (0~3600) seconds.

  6. “1# power priority”, “Auto/Manual”, “No priority” and “2# power priority” can be set via the controller front panel.

  7. The closing output signal can be set as on intervals or as continuous output.

  8. Applicable for 2 isolated neutral lines.

  9. Auto/Manual mode. In manual mode, ATS transfer can be implemented via panel pushbutton.

  10. LEDs mounted on the front panel can clearly show ATS running status.

  11. Forced Open input port has been designed; When the input port is active, the switch will be Breaking position forcedly (woks for the ATS with Breaking Position).

  12. AUX.OUTPUT 1 and AUX.OUTPUT 2 can be configured to make it easy to transfer power supply.

  13. The output contact capacity of 1# and 2# power supply transfer relay (1#CLOSE, 2#CLOSE) is 5A AC250V, passive contact, can be directly used in driving switch to transfer.

  14. The output contact capacity of the Genset start relay (GENS START) is 7A AC250V/7A DC28V, passive N/C contact.

  15. Suitable for various AC systems (3 phase 4-wires, 2-phase 3-wires and single-phase 2-wire).

  16. Modular design, retardant ABS plastic shell, pluggable terminal, built-in mounting,compact structure with easy installation.

Payment & Security

American Express Apple Pay Google Pay Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Estimate shipping

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

You may also like

Recently viewed