Support for 0-10 V & 4-20mA oil pressure senders.
It provides flexibility for use with multiple sensors and engine types.
Ensures the display continues to operate in extreme cold weather conditions.
Provides true generator and mains (utility) sensing.
Generator/load current monitoring & protection.
Product description
Specification:
Material: Plastic
Weight: 526g/18.6oz
Model: DSE6120
DC Supply: continuous voltage rating 8 V to 35 V Continuous
Cranking Dropouts: Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recover to 5 V. This is achieved without the need for internal batteries. LEDs and backlights will not be maintained during cranking.
Maximum Operating Current: 100 mA at 12 V, 105 mA at 24 V
Maximum Standby Current: 60 mA at 12 V, 55 mA at 24 V
Maximum Sleep Current:40 mA at 12 V, 35 mA at 24 V
Generator & Mains(Utility):
Voltage Range: 15 V to 415 V AC (Ph to N); 26 V to 719 V AC (Ph to Ph)
Frequency Range: 3.5 Hz to 75 Hz
Inputs: Digital Inputs A to F, negative switching analog input A
Configurable as:
Negative switching digital input
0 V to 10 V
4 mA to 20 mA
0 | to 240 |
Analogue Inputs B to D
Configurable as: Negative switching digital input 0 | to 480 |
Outputs:
Output A (Fuel)
10 A short term, 5 A continuous,
at supply voltage
Output B (Start)
10 A short term, 5 A continuous,
at supply voltage
Auxiliary Outputs C, D, E & F
2 A DC at a supply voltage
Package List:
1 x Generator Controller
2 x Set Screws